5.22.10 PLUMBING PIPING AND PUMPS DESIGN AND CONSTRUCTION ...
B. Reference ASME A17.1 for elevator sumps and sump pump requirements. 1.02 Codes and Standards 2.01 Pipes and Pipe Fittings A. Pipe Size 2" and Smaller 1. Copper tube; 5.22.10 – PLUMBING PIPING AND PUMPS DESIGN AND CONSTRUCTION STANDARD ... Access This Document
Little Giant Big John Submersible Sump Pump - Gempler's
Little Giant® Big John® Submersible Sump Pump OWNERS MANUAL FOR 6-CIM-R 6-CIA-RFS 8-CIM-R CAUTION: READ SAFETY GUIDELINES AND INSTRUCTIONS CAREFULLY AUTOMATIC PUMP as the discharge size to reduce pipe friction losses. Smaller pipe will restrict capacity and reduce pump performance. ... View Doc
Owner’s Manual 12 Volt Battery Backup Sump Pump System
1 - 12 volt battery backup sump pump 1 - Control/alarm panel 1 - Float switch 1 - 12 volt battery charger 1 - Extra fuse Thread the Battery Backup Sump Pump onto thedual size pipe tee provided. Once the pump is threaded tight and setting parallel to the discharge pipe, turn the ... Read Document
Sump Pump Questions - Nd.gov
Sump Pump Questions How do you check or test a sump pump? A. First, make sure the outlet pipe is not frozen shut or plugged and that it directs water away from the house. What size pump should I have for my house? A. There is no "correct" size. ... Read Document
Sump Pump Sizing - Engineering ToolBox
Data Sheet Booster Pump Sizing Print_Area_MI Pick Pipe Type Sch. 40 Steel Duraplus Plastic Pipe Type K Copper Pipe Type L Copper Pipe Schedule 10 Stainless Steel ... Get Doc
How To - Plumbing - PVC Pipe - Submersible Sump Pump ...
Demonstration of basement plumbing installation of a submersible sump pump hard-piped with 1.5" PVC tubing, with check-valve, flex connector, elbows, and han ... View Video
Mercedes-Benz OM 138 - Wikipedia
The fuel is pumped to the injection nozzels by a Bosch size A injection pump, It has a small oil pipe with a sieve and a funnel to pump the oil from the sump through the oil filter into the main lubrication oil pipe. ... Read Article
Sump Design Criteria - City Of Lethbridge
Sump Design Criteria a) Sump Pit Details .1 Sump pits are to be a minimum of 750 mm (30”) drain with the invert of the pipe located above the centre of the sump pits’ height. Sump Pump .1 Provide a sump pump (column or submersible type) ... Return Doc
Sump Pump Pipe Relief Hole - YouTube
How To, Sump Pump Set Up and Install, Step by Step Instruction Including Perforated Pipe Connection - Duration: 13:19. appledrains 211,535 views ... View Video
Sump Pumps - Pump Products
Discharge pipe should be the same size as the pump discharge to insure optimum performance. is a major cause of sump pumps failing to pump after long periods of inactivity such as If your sump pump only operates seasonally ... Fetch Here
DIY Overflow Box Plans - About.com Home
A saltwater aquarium systems filtration set up that can be installed with or without standpipes, as well as plumbed in combination with a sump, protein skimmer or other filtering equipment, here is a collection of various do-it-yourself overflow box plan designs. ... Read Article
Sizing Pumps And Pipes
Sizing Pumps and Pipes The pump and pipes are sized to provide for the estimated peak flow rate. The peak flow rate can be estimated as follows: TO USE: Move downward in pipe length column and horizontally on flow rate, read pipe size in area where lines intersect. EXAMPLE: ... Get Document
SIZING CALCULATIONS FOR SUMP PUMP AT SUMP PIT FOR PROPOSED ...
Sizing calculations for sump pump at sump pit for proposed erection of a 2 storey detached dwelling house with basement and swimming pool on lot ... Access Document
Sump Pumps - WATERPROOF! Magazine
The ˛ rst pump fails. In a few areas of the country, where the sump pit only ˛ lls occasionally, battery-operated pumps are used as the primary. ... Return Document
Hydromatic PUMP SIZING MADE EASY
Hydromatic ® PUMP SIZING MADE EASY HWP-81 covers the steps that need to be taken to accurately select the correct sump pump, sewage pump, the gPM flow, pipe size and pipe material, all straight pipe, fittings, valves, ... Retrieve Here
MYERS SIZING TABLES - Myers Pumps And Systems
MYERS ® SIZING TABLES Sewage & Effluent Pumps SRM4 2” Discharge, 2 1 check valve, 1 gate valve, 5 elbows, and PVC pipe SDR21 (C=150) MYERS ® SUMP PUMPS. 4 ME3H ME3F 1-1/2” Discharge, 1-1/2” Pipe 1-1/2 2” Pipe NOTE: Do not size pump to right of heavy black line if liquid being ... Doc Viewer
SP-330 Submersible SP-330D Sump Pumps SP-500 SSP-1000
And understanding how your sump pump works. Safety Signal Words means if the safety information is not is the proper size. 2. Make sure the electrical outlet is grounded and is rated for 115 volts and at least 15 amps. The out- ... Doc Viewer
Suction System Design - WYCO Pump
PC33 Suction System Design Page 1 of 8 April 21, centrifugal pump. Selection of the discharge pipe size is primarily a matter of economics. the location of the pipe in the sump and the actual dimensions of the sump are also important in preventing vortexing and/or ... Document Retrieval
For New Or Replacement Sewage Pumps
Sump and Sewage Pump Manufacturers Association For New or Replacement Sewage Pumps AB AB column, follow across to the number below the pipe size being used. This number represents the Friction Head per 100 feet of pipe. Multiply this ... Content Retrieval
Sump Pump Selection Guide - Discharge Diameter
What diameter discharge pipe do you have? LANGUAGE It is important that we always look at the inside diameter when determining the pipe size. Installing new pipe for the sump pump. If you are installing a sump pump where there was none before, ... Retrieve Doc
Large Submersible Pump Station Design Guide.pdf - Gsengr.com
Design recommendations for pump stations with large centrifugal wastewater pumps. To avoid pre-swirl into the pump chamber, the inlet pipe must have a straight length of five pipe diameters design varies with the number of pumps and pump size. If the piping system and the sump location ... Access Doc
Aquarium Sump & Overflow Box Setups
Information about the many ways to add or install a sump, an overflow box, as well as combination setups in saltwater aquarium and reef tank systems. ... Read Article